Abstract

Results of a prior experiment and its conclusions are re-examined by two researchers. Charge deposition on isolated capacities due to rapid discharge of ?non-sparking? Tesla coils is tested a second time using a number of different techniques and instruments. This new, joint effort contradicts the prior work. Explanations are given as to why the prior conclusions were found to be in error.